Plan your network
vBase uses three kinds of network. Plan the addresses before you install.
Management network
Section titled “Management network”Each server’s management port, with a fixed address. The web console, the API and SSH are reached here, and the servers talk to each other here.
- Use a network (or VLAN) of its own that only administrators reach.
- The setup wizard asks for the address, gateway and DNS server.
The router’s uplink
Section titled “The router’s uplink”vBase runs its router (VyOS) as a VM. Its uplink connects the tenants’ private networks to the internet.
- A second server port for it keeps tenant traffic off the management network.
- Give the router a fixed address on its uplink network (a DHCP reservation on your firewall is fine). Routes to it must not change when a lease renews.
Public addresses
Section titled “Public addresses”For services reached from the internet (floating IPs, the HTTPS edge), route public addresses to the router’s uplink address. The router answers for them; your firewall only needs a static route per address (or range) and to allow the traffic through.
Between servers
Section titled “Between servers”With two or more servers, a direct, fast link between them (10 Gb/s or more) carries the private networks’ tunnels and Ceph’s copies, so they don’t compete with management traffic.
Example
Section titled “Example”One small layout, with a UniFi gateway in front:
| Network | VLAN | Addresses | Used for |
|---|---|---|---|
| Management | 250 | 10.250.0.0/24, servers at .10, .11 |
console, API, SSH |
| Router uplink | 251 | 10.251.0.0/30, router at .2 |
tenant traffic to the internet |
| Public | (routed) | a small public range, routed to 10.251.0.2 |
floating IPs, the edge |
| Server to server | (direct cable) | private | tunnels, Ceph |
The private networks tenants create (VPCs) use their own ranges, chosen in the console. They must not overlap the ranges above; vBase refuses ones that do.
vBase by ONECOMET© 2026 ONECOMETDocs licensed CC BY 4.0Releases